# Fire Extinguisher Maintenance Checklist

Log each extinguisher on site with its location, type and serial number. Record the dated monthly visual check and the annual maintenance, add photos and signatures, and download one PDF.

A fire extinguisher maintenance log records, for each portable extinguisher, the monthly visual inspection and the annual maintenance check that OSHA 29 CFR 1910.157(e) requires employers to carry out.

- OSHA requires portable extinguishers to be visually inspected monthly (1910.157(e)(2)).
- OSHA requires an annual maintenance check, and the employer records the annual maintenance date and keeps the record for one year after the last entry or the life of the shell, whichever is less (1910.157(e)(3)).
- Stored pressure dry chemical extinguishers that need a 12-year hydrostatic test are emptied and maintained every 6 years (1910.157(e)(4)).
- NFPA 10 is the standard for portable fire extinguishers; this page records checks and does not reproduce it.

Online tool: https://signvisit.com/fire-extinguisher-maintenance-checklist/

A fire extinguisher maintenance checklist is the record that each extinguisher was looked at every month and serviced every year. In a US workplace the rules are in OSHA 29 CFR 1910.157(e): a monthly visual inspection and an annual maintenance check, with the annual date recorded.

This page is a log, not a single inspection form. Add one block for each extinguisher: location, type, serial number and size. In each block enter the date and initials of the monthly check and set seven checks to OK, Fault or N/A. Then record the annual maintenance: date, who did it, six checks and the next six-year or hydrostatic test date. Add photos of the tag or any fault, sign and download one PDF for the site.

## How to fill in the fire extinguisher log

1. Enter your business name and contact. Tick the box to keep them on this device, so the next round starts filled in.
2. Check the number and date, then enter the site or building and who is inspecting.
3. In the first extinguisher block, enter the location, the type, the serial number and the size or rating. Copy the serial number from the label or the service tag.
4. Enter the date of the monthly check and your initials, then set each of the seven checks to OK, Fault or N/A. Choose Fault for anything that is missing, blocked, damaged or out of range.
5. Use Add another extinguisher for every further unit on the site. Each block keeps its own dates, so you can tell at a glance which unit was checked and which was not.
6. When the annual maintenance has been done, enter its date and who did it, set the six checks, and note the next date for six-year maintenance or hydrostatic testing.
7. Write what needs doing in the summary, for example an extinguisher to be recharged, replaced or moved, and add a remark for the unit concerned.
8. Photograph the service tag and any fault, sign, and download the PDF. Keep the file as the dated record, and start a new log for the next month.

## What does OSHA require?

OSHA 29 CFR 1910.157(e) makes the employer responsible for inspection, maintenance and testing of portable fire extinguishers in the workplace. They are visually inspected monthly and given an annual maintenance check. The annual maintenance date is recorded, and the record is kept for one year after the last entry or the life of the shell, whichever is less. Stored pressure dry chemical extinguishers that need a 12-year hydrostatic test are emptied and given the maintenance procedures every 6 years, and hydrostatic testing follows section (f) of the same rule (US OSHA).

## What is checked each month?

The usual visual items are that the extinguisher is in its place, can be seen and reached, its operating instructions face out, the gauge or indicator reads in the operable range, the pin and tamper seal are in place, there is no visible damage, corrosion or leak, and it feels full when lifted. These are common items rather than a quotation of the rule. NFPA 10 is the named standard for portable fire extinguishers and sets its own detail, so follow it and the maker&#39;s label where they ask for more.

## What happens at the annual maintenance?

A trained person examines the extinguisher thoroughly, looking at the shell, valve, hose and nozzle, checking the pressure, and tags it with the date. This log records that it was done, by whom and when, and the next due date for six-year maintenance or hydrostatic testing. It does not replace the tag on the unit or the service company&#39;s own report, which stay as the proof of the work.

## What should the monthly record show?

At minimum the date, which extinguisher, who looked at it and whether anything was wrong. Each block in this log has a dated entry, the initials of the person who checked, the result of every check and a remark for the unit. When a unit fails a check, write what you did about it, for example that it was swapped for a charged spare or sent for recharging, so the next person sees the history.

## How is this different from an inspection checklist?

An inspection checklist is a one-off form for one extinguisher or one round. This log keeps every extinguisher on the site in one document, with separate dated entries for the monthly and annual records and a remark for each unit. It suits a site with many units, such as a shop, a warehouse or an apartment building, where the question is which ones are due.

## Is this a legal form?

No. It is a record of the checks you ticked. The rules that apply depend on the site and the country, so check them and follow the maker&#39;s instructions.

## Frequently asked questions

### How often must fire extinguishers be maintained?
Under OSHA 1910.157(e) they are visually inspected monthly and get an annual maintenance check, and the date of the annual maintenance is recorded. Some types also need the six-year maintenance or hydrostatic test.

### Can I log more than one extinguisher?
Yes. Add a block for each one with its own location, type and serial number. All blocks are printed in the same PDF.

### Does the PDF include the signature and photos?
Yes. Up to 12 photos with captions and the signatures are printed in the PDF, which is built on your device. Nothing is uploaded.

### Do I still need the service tag?
Yes. The tag stays on the extinguisher and the service company&#39;s report stays with your records. This log is your own record of the checks.

### How long should I keep the record?
OSHA 1910.157(e) says to keep the annual maintenance record for one year after the last entry or the life of the shell, whichever is less. Many sites keep the monthly PDFs for the same time; check the rule that applies to you.

### Can I reuse the log next month?